SOFFIT (Take down and renew to 60 minutes)

SOFFIT (Take down and renew to 60 minutes)

Take down the existing soffit to the # specify exact position/room #. Construct a new soffit having a minimum fire resistance of 60 minutes, using approved materials plastered and set to a smooth finish. Standard of construction to be in accordance with Appendix I to this schedule. Junctions with adjacent structural elements shall be constructed so that the structure maintains its fire integrity in the event of a fire, and is imperforate and sealed against the passage of the products of combustion on completion. Fill any gaps around cables and pipes with intumescent past


SOFFIT (Take down and renew to 60 minutes)
https://plumobsidian.github.io/p/5d3f1c9b6ed94d3e8e16d6df77fda73f/
Author
Mr Bog
Posted on
May 11, 2020