SPANDREL (upgrade to 60 minutes)

SPANDREL (upgrade to 60 minutes)

Upgrade the existing spandrel between basement and ground floors to provide a minimum standard of fire resistance of 60 minutes. The protection is to be provided on the basement/down side of the spandrel. Standard of construction to be in accordance with Appendix I to this schedule. Junctions with adjacent structural elements, including soffit of staircase, shall be constructed so that the structure maintains its fire integrity in the event of a fire, and is imperforate and sealed against the passage of the products of combustion on completion. Fill any gaps around cables and pipes with intumescent paste.


SPANDREL (upgrade to 60 minutes)
https://plumobsidian.github.io/p/febf399a774c41d98d2c6ace9fddedec/
Author
Mr Bog
Posted on
May 11, 2020