CUPBOARD STORE (single)(make up soffit ceiling to 30 minutes resistance)

CUPBOARD / STORE (single)(make up soffit / ceiling to 30 minutes resistance) Make up to a standard of fire-resistance of at least 30 minutes the soffit / ceiling within the cupboard
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

CUPBOARD STORE (single)(make up partitions to 30 minutes resistance)

CUPBOARD / STORE (single)(make up partitions to 30 minutes resistance) Make up the partitions within the cupboard/store situated # specify position #. to a standard of fire resistance of at
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

REPAIR DAMAGED PLASTER TO CEILING WALL SOFFIT CORNICE

REPAIR DAMAGED PLASTER TO CEILING / WALL SOFFIT / CORNICE Hack off all # specify defect e.g. unkeyed, damaged etc #plaster to the # specify position e.g. wall, ceiling, soffit, cornice etc #
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

SOFFIT (underdraw to provide 30 minute fire resistance)

SOFFIT (underdraw to provide 30 minute fire resistence) Upgrade the existing soffit #specify position # by underdrawing with 12.5mm plasterboard. Scrim joints with 90mm hessian scrim and set with 5mm
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Glazing in partition (replace upgrade)

Glazing in partition (replace/ upgrade) Remove the existing unprotected glazing from the partition # specify exact position # along with associated beading etc. and suitably dispose of the materi
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Change catches locks to door

Change catches/locks to door Remove the existing lock (s) from the ….. door. Fit a new latch with a positive latching mechanism comprising steel or brass nib (not rollerball catch) which is prefe
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Worktop Sockets Kitchen

Fit X of double sockets (above worktop level) Provide (X X No.) of sockets. Each kitchen area must be provided with a minimum of 6 double 13 amp electric socket outlets. At least two of the sockets ar
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 23 - Electrical Hazards
#electrical_hazards

Windows Safety Catches

Safety Catches Provide safety catches to the relevant windows referred to above. The safety catches must be such that they can be easy to override, by an adult, in the event of a fire occurring. The c
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels
#falls_between_levels

Windows Cill heights

Windows – Internal Cill heights The cill heights to the double hung sash windows in XXX are less than 1.1 metres above internal floor level. This would facilitate a fall from an openable window by a v
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels
#falls_between_levels

Landings Balustrades

Landings with Balustrades Replace all missing balusters to the whole of the staircase and ensure there no gaps of more 100mm between any balusters
2023-11-05
Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels
#falls_between_levels