Worktop Sockets Kitchen Fit X of double sockets (above worktop level) Provide (X X No.) of sockets. Each kitchen area must be provided with a minimum of 6 double 13 amp electric socket outlets. At least two of the sockets ar 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 23 - Electrical Hazards #electrical_hazards
Windows Safety Catches Safety Catches Provide safety catches to the relevant windows referred to above. The safety catches must be such that they can be easy to override, by an adult, in the event of a fire occurring. The c 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels #falls_between_levels
Windows Cill heights Windows – Internal Cill heights The cill heights to the double hung sash windows in XXX are less than 1.1 metres above internal floor level. This would facilitate a fall from an openable window by a v 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels #falls_between_levels
Landings Balustrades Landings with Balustrades Replace all missing balusters to the whole of the staircase and ensure there no gaps of more 100mm between any balusters 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels #falls_between_levels
Windows Restrictors Windows’ Restrictors Provide suitable proprietary restrictors to limit the window openings to XXX [bottom sashes] to a maximum of 100 mm (10cm) to [above] windows: The following lists of windows have 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels #falls_between_levels
Roof Guarding Guarding to Roof Terraces Provide a weather resistant balustrade to the roof terrace that is used for recreation. The guarding should at least be 1100mm high, designed and constructed so as to discour 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 22 - Falls between Levels #falls_between_levels
Various Generic (Useful) Various Generic (Useful) Provide in the bathroom, a suitable wash hand basin provided with an adequate supply of hot and cold water and properly connected to the drainage system by means of a trapped 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Sewer Investigate Sewer investigation Thoroughly investigate the private sewer serving properties ……….. inclusive, by means of a closed circuit television camera or other suitable alternative method to establish the co 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 15 - Domestic Hygiene, Pests and Refuse #domestic_hygeine_pests_and_refuse
Drains Chamber New inspection chamber Construct within the ……….. an inspection chamber of suitable size using sound, 225mm (9in) semi-engineering brickwork set in Portland cement mortar, with [a] a removable air tig 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 15 - Domestic Hygiene, Pests and Refuse #domestic_hygeine_pests_and_refuse
Drains Interceptor Clearing eye for a drain interceptor. Provide and fix, with suitable mastic, a properly fitting stopper to the clearing eye of the …………. interceptor. 2023-11-05 Standard Clauses For Housing Act Use - HHSRS > 15 - Domestic Hygiene, Pests and Refuse #domestic_hygeine_pests_and_refuse