Kitchen Take a look at Food Safety hazards clauses I have here too as many of them cross over with DH,P&R. 2022-06-28 Standard Clauses For Housing Act Use - HHSRS > 15 - Domestic Hygiene, Pests and Refuse #domestic_hygeine_pests_and_refuse
Provide handrails to stairs Provide handrails to stairs Provide and securely install a suitable handrail beside each staircase flight, which is not already provided with a handrail. Each new handrail to be positioned at a height 2021-10-05 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Examine & upgrade existing door frames and install new 30 minute fire door Examine & upgrade existing door frames and install new 30 minute fire door Remove and suitably dispose of the following doors: - - Remove the architraves from the room-side of the door openings an 2021-10-05 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Replace existing 30 minute door and frame Replace existing 30 minute door and frame Remove the existing door and frame # specify exact position # and suitably dispose of them. Take care to endure that the door does not contain any asbestos ma 2021-05-17 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Seal doorway (Remove door and seal opening) Seal doorway (Remove door and seal opening) Remove the existing door and frame. # specify exact position # Seal opening by means of fire resisting construction having a minimum fire resistance of 30 m 2021-03-10 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Provide lobbies outside individual rooms Provide lobbies outside individual rooms Provide the following rooms …., with fire protecting lobbies of minimum standard of fire resistance of 30 minutes. The lobbies are to be constructed outside th 2021-03-10 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
PARTITION (make up single partition to 60 minutes)(high risk areas) PARTITION (make up single partition to 60 minutes)(high risk areas) Make up to a standard of fire resistance of at least 60 minutes the partition # specify position #. The protection is to be provided 2021-03-10 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
AFD For Specific Property Types To be re-written in accordance to current guidance 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Overhaul emergency lighting installation Overhaul emergency lighting installation Employ a competent person to examine and test the emergency lighting installation. Replace all discoloured or damaged lens/diffusers, and other defective 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Emergency lighting Emergency lighting Install an emergency lighting, so that it will automatically illuminate the entire protected escape route, in the event of any power failure to the conventional artificial lighting, 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety