Install a Sprinkler System 1 Install a Sprinkler System These are recommended in properties where there is a significant risk of arson, or to compensate where it is difficult to provide adequate structural fire integrity i.e. lis 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Intumescent Fire Hoods Intumescent fire hoods INSTALLING RECESSED LUMINAIRES IN CEILINGS by Bill Allan THE IEE receives a number of enquiries from designers and installers and others regarding the application of Regulation 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Seal gaps and voids Seal gaps and voids Infill all gaps between walls, walls and ceilings, gaps around pipes penetrating walls and ceilings, gaps around fire-resisting doorsets with suitable intumescent filler or sealant 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
FIRE RESISTING SCREEN & DOOR across the STAIRCASE FIRE RESISTING SCREEN & DOOR across the STAIRCASE Construct a fire resisting screen across the ……. floor landing to separate the ……. floor from the accommodation below. The screen is to have a min 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SPANDREL (upgrade to 60 minutes) SPANDREL (upgrade to 60 minutes) Upgrade the existing spandrel between basement and ground floors to provide a minimum standard of fire resistance of 60 minutes. The protection is to be provided on th 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SPANDREL (upgrade to 30 minutes) SPANDREL (upgrade to 30 minutes) Upgrade or renew the existing spandrel between basement and ground floors to provide a minimum standard of fire resistance of 30 minutes. The protection is to be provi 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Screens and Spandrels SECTION E - PROTECTION WITHIN BASEMENT AND FIRE RESISTING SCREEN ACROSS STAIRCASE 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SOFFIT (repair cracked lath and plaster to 30 minutes) SOFFIT (repair cracked lath and plaster to 30 minutes) Rake out the crack(s) in the plaster to the soffit to the # specify exact position #, key to receive new plaster, remove any loose or otherwise d 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SOFFIT (Take down and renew to 60 minutes) SOFFIT (Take down and renew to 60 minutes) Take down the existing soffit to the # specify exact position/room #. Construct a new soffit having a minimum fire resistance of 60 minutes, using appro 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
PROVIDE 30 MINUTE PROTECTION TO CELLAR CEILING (general clause) PROVIDE 30 MINUTE PROTECTION TO CELLAR CEILING (general clause) Carry out all works necessary to ensure the ceiling throughout the cellar has a minimum fire resistance of 30 minutes. Provide and fix 1 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety