Screens and Spandrels SECTION E - PROTECTION WITHIN BASEMENT AND FIRE RESISTING SCREEN ACROSS STAIRCASE 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SOFFIT (repair cracked lath and plaster to 30 minutes) SOFFIT (repair cracked lath and plaster to 30 minutes) Rake out the crack(s) in the plaster to the soffit to the # specify exact position #, key to receive new plaster, remove any loose or otherwise d 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
SOFFIT (Take down and renew to 60 minutes) SOFFIT (Take down and renew to 60 minutes) Take down the existing soffit to the # specify exact position/room #. Construct a new soffit having a minimum fire resistance of 60 minutes, using appro 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
PROVIDE 30 MINUTE PROTECTION TO CELLAR CEILING (general clause) PROVIDE 30 MINUTE PROTECTION TO CELLAR CEILING (general clause) Carry out all works necessary to ensure the ceiling throughout the cellar has a minimum fire resistance of 30 minutes. Provide and fix 1 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
CEILING (PLASTERBOARD) (renew defective ceiling complete to provide 30 minutes fire protection) CEILING (PLASTERBOARD) (renew defective ceiling complete to provide 30 minutes fire protection) Take down defective plasterboard ceiling # specify where (? throughout basement or ? specify room)# and 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
CEILING (LATH & PLASTER) (renew defective ceiling complete to provide 30 minutes fire resistance) CEILING (LATH & PLASTER) (renew defective ceiling complete to provide 30 minutes fire resistance) Take down defective lath and plaster ceiling # specify where (? throughout basement or ? specify r 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
CEILING (underdraw to provide 60 minute fire resistance) CEILING (underdraw to provide 60 minute fire resistance) Upgrade the existing ceiling to the # specify position # by underdrawing with 12.5mm plasterboard screwed or nailed to joists. Joints between n 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
CEILING (single) (Examine construction and if sub-standard upgrade) CEILING (single) (Examine construction and if sub-standard upgrade) Carry out a thorough examination of the ceiling to # specify position #. If found to be of a construction having a fire resistance o 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
Repair cracked lath and plaster CEILING (single) Repair cracked lath and plaster CEILING (single) Rake out the crack(s) in the plaster to the ceiling # specify exact positions #, key to receive new plaster, remove any loose, unkeyed, damp, perished 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety
CEILING (single) (take down and renew to 60 minutes) CEILING (single) (take down and renew to 60 minutes) Take down the existing ceiling to the # specify exact position/room #. Construct new ceilings, each having a minimum fire resistance of 60 min 2020-05-11 Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety #fire_safety