Ask Chadwick
  • Home
  • Archives
  • Categories
  • Tags
  • About
  • contact
  • Links

Repair cracked lath and plaster CEILING (single)

Repair cracked lath and plaster CEILING (single) Rake out the crack(s) in the plaster to the ceiling # specify exact positions #, key to receive new plaster, remove any loose, unkeyed, damp, perished
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

CEILING (single) (take down and renew to 60 minutes)

CEILING (single) (take down and renew to 60 minutes) Take down the existing ceiling to the # specify exact position/room #. Construct new ceilings, each having a minimum fire resistance of 60 min
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

CEILING (single) (take down and renew to 30 minutes)

CEILING (single) (take down and renew to 30 minutes) Take down and remove the existing non half-hour fire-resisting ceiling # specify exact position/room #. Construct a new ceiling, having a mini
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Repair cracked lath and plaster partition

Repair cracked lath and plaster partition Rake out the crack(s) in the plaster to the partition # specify exact positions #, key to receive new plaster, remove any loose or otherwise defective plaster
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

PARTITION (Examine construction and if sub-standard upgrade to 30 minutes)

PARTITION (Examine construction and if sub-standard upgrade to 30 minutes) Carry out a thorough examination of the partition # specify position #. If found to be of a construction having a fire resist
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

PARTITION (make up single partition to 30 minutes)

PARTITION (make up single partition to 30 minutes) Make up to a standard of fire resistance of at least 30 minutes the partition # specify position #. The protection is to be provided on the risk side
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Provide lobbies outside individual rooms 1

Provide lobbies outside individual rooms Remove existing doors and frames from the following positions ……….. , Provide the rooms listed immediately above with a shared fire protecting lobby of minimum
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Replace door with door containing vision panel

Replace door with door containing vision panel Remove the existing door and frame to # specify exact position of door # and suitably dispose of them. Provide and fix replacement fire resistant door an
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Remove hook or door holder (General clause)

Remove hook or door holder (General clause) Remove all door wedges, hooks and ties or other devices capable of hold self-closing fire doors in the open position. Ensure that each door is fitted with a
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Change self-closer to door

Change self-closer to door Replace the existing self-closing device from the # specify exact position of door# with a suitable replacement hydraulic top of door self-closing device in accordance with
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety
1…1718192021…25

Search