Upgrade existing purpose-designed and constructed British Standard fire door

Upgrade existing purpose-designed and constructed British Standard fire door N.B. Where purpose-designed and constructed British Standard fire doors have been fitted in the past to an earlier 30 minut
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Replace door & frame (60 minutes)

Replace door & frame (60 minutes) Remove the door and frame and suitably dispose of it. Take care to endure that the door does not contain any asbestos materials. If the door does contain suspect
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Replace doors & frames (60 minutes)

Replace doors & frames (60 minutes) Remove all doors and frames from the positions listed immediately below and suitably dispose of: specify exact door positions # Take care to endure that the doo
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Examine & upgrade existing doors in listed buildings

Examine & upgrade existing doors in listed buildings Remove and examine the following doors to be protected and re-used. Remove beads, fill any cracks or splits and voids in the door panels and be
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Upgrading non-fire resistance doors

Instruct a qualified person to carry out an assessment of the existing doors listed immediately below for suitability to be upgraded to 30 minutes fire resistance OR 60 minutes fire resistance (Delete
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Upgrading non-fire resistance door

Upgrading non-fire resistance door Instruct a qualified person to carry out an assessment of the existing door # specify exact position # for suitability to be upgraded to 30 minutes fire resistance O
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Listed Building Doors

DOORS/FRAMES NEEDING TO BE RETAINED FOR AESTHETIC REASONS E.G. LISTED BUILDINGS OR EXISTING BUILDING OF SUBSTANTIAL CONSTRCTION. NB The upgrading of non-fire-resisting door assemblies should be a
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Revised Guidance

Introductory Paragraph The Regulatory Reform (Fire Safety) Order 2005 applies to the common parts of any house in multiple occupation, and requires responsible persons to “take such general fire preca
2020-05-11
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

AFD and Lighting

2020-04-30
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety

Cupboards etc

2020-04-30
Standard Clauses For Housing Act Use - HHSRS > 24 - Fire Safety
#fire_safety
1…1819202122…24