Yard Paving 3 Yard Paving Hack out cracks to existing XXX. Infill and make good flush with surrounding areas. 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 20 - Falls on the Level #falls_on_the_level
Yard Paving 2 Yard Paving Break up and remove from site the existing XXX surface XXX. Reduce level as necessary. Provide, spread and consolidate 100mm new hardcore and lay 75mm concrete trowelled and floated smooth 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 20 - Falls on the Level #falls_on_the_level
Repair sloping Flooring Open up and examine the sloping floor. Thoroughly repair and secure floor joists. Provide and fix firring pieces as necessary. Renew defective floorboards and refix sound floorboards. Renew or refix s 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 20 - Falls on the Level #falls_on_the_level
Provide Sink and base unit Provide Sink and base unit Provide and install new sink and base unit, minimum dimensions of sink to be 500mm x 600mm, complete with waste, overflow, taps, plug and chain. Ensure connection to hot and 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Provide Sink Provide Sink Provide and install new suitable sink, minimum dimensions 500mm x 600mm, with waste, overflow, taps, plug and chain. Provide and fit trap, connect waste pipe to trap, run and properly con 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Waste pipes Generic Waste pipes Generic Renew defective length of XXX waste pipe in suitable materials, test and leave in proper working order. Overhaul defective XXX waste pipe. Repair any leaking sections, cleanse and 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Soil and Waste Pipes – Drainage Generic Soil and Waste Pipes – Drainage Generic Provide and fix a new soil pipe to the XXX. The new soil pipe to be 100mm diameter properly connected to the underground drainage using a suitable connector. En 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Provide Soil and Vent Pipe Provide Soil and Vent Pipe Provide, erect and fix soil and vent pipe complete with necessary fittings, bosses and WC branch and connect to existing drainage. Cut hole in external wall and extend WC br 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Provide Manhole Provide Manhole Break up paving as necessary, and excavate to expose existing drain run. Construct an adequate manhole. Trim, level and ram bottom of excavation. Lay 150mm concrete bed, build one bric 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage
Bath Fittings Fittings Supply XXX mm plug and suitable length of retaining chain to the… . Take out the trap to the bath in the XXX. Supply and fit a 38mm plastic waste trap properly connected to the existing waste 2020-04-30 Standard Clauses For Housing Act Use - HHSRS > 17 - Personal Hygiene, Sanitation and Drainage #personal_hygeine_sanitation_and_drainage